This morning I woke up to my phone using mobile data and my home assistant automations not working. Initially I thought it the power was out, but I could turn on the lights just fine. I checked my UniFi app and saw that the server was not connected to the network at all. This meant that the cable got unplugged, the switch isn’t working, or the server isn’t working. It said the switch was connected and another device was connected to the switch so that narrows it down to just 2 cases. So I opened my server closet in the basement and immediately noticed something was wrong. I couldn’t figure out what was wrong but I just felt like something was wrong. Everything was plugged in, the network switch lights were blinking like normal, my raspberry pi was running just fine, even the server indicator lights were on. My main server is an old gaming PC so it has a glass side panel so I looked inside and I could see the fan spinning, but I could not hear it. Usually I have it set to full speed and I can hear full speed very well. I tried rebooting the server with the power button and the fans didn’t go to full speed. As a last resort, I brought down a keyboard and monitor. As soon as I plugged in the monitor, I saw that there was a prompt to set the time on the BIOS! Picture of the prompt In my opinion, this was the stupidest reason for an outage.

Further investigations

I dug a little deeper and discovered that the BIOS had been reset during a power outage right before all of this happened. So far I have consulted the motherboard manual and found absolutely nothing about this. After a bit of research, I think it could have been that the CMOS battery has died. This is a really simple fix but I don’t have the replacement battery right now. This means that I will have the same exact issue after the next power outage unless I replace the battery.

Preventing this in the future

From what I can see, I just need to replace the CMOS battery. But this computer has been running for over 4 years, so what is stopping this from happening again around 2028? The most effective solution is going to be preventing power outages in the first place. This can be done using a battery backup or a standby generator. Standby generators will last longer during a power outage but are typically more expensive and harder to setup than a simple battery backup.

  • Dave.@aussie.zone
    link
    fedilink
    English
    arrow-up
    158
    arrow-down
    1
    ·
    edit-2
    3 months ago
    1. Replace CMOS battery.
    2. Get small UPS.
    3. Discover that small UPS’s fail regularly, usually with cooked batteries.
    4. Add maintenance routine for UPS battery.
    5. Begin to wonder if this is really worth it when the rest of the house has no power during an outage.
    6. Get small generator.
    7. Discover that small generators also need maintenance and exercise.
    8. Decide to get a whole house battery backup a-la Tesla Powerwall topped off by solar and a dedicated generator.
    9. Spend 15 years paying this off while wondering if the payback was really worth it, because you can count on one hand the number of extended power outages in that time.
    10. In the end times a roving band of thugs comes around and kills you and strips your house of valuable technology, leaving your homelab setup behind and - sadly - without power. Your dream of unlimited availability has all been for nought.

    Conclusion: just replace the CMOS battery on a yearly basis during planned system downtime.

    • catloaf@lemm.ee
      link
      fedilink
      English
      arrow-up
      30
      arrow-down
      1
      ·
      3 months ago

      CMOS batteries last a lot longer than a year. Unless the system has been unplugged for a long time, they should be good for several years. I’m sure there’s actual data out there somewhere.

      But yeah, a lot of people think “oh I’ll just put a UPS on it”. They don’t consider that unless you get a really big UPS, they’re only good for very short outages, seconds or minutes, to bridge the gap between the outage and your generator coming on (or the mains power coming back if it was just a flicker).

      Also, the batteries in them need to be replaced every 3-5 years.

      • Dave.@aussie.zone
        link
        fedilink
        English
        arrow-up
        10
        ·
        3 months ago

        Yeah , it’s really a little strange in OPs case, I can’t really recall changing a CMOS battery in ages, like decades of computer use.

      • yonder@sh.itjust.works
        link
        fedilink
        English
        arrow-up
        5
        ·
        3 months ago

        I bought a small APC UPS about a year ago and am glad I did. In my area, very brief outages are somewhat common so a small UPS will work for the majority of outages.

    • rambos@lemm.ee
      link
      fedilink
      English
      arrow-up
      11
      ·
      3 months ago

      What about UPS just for CMOS battery? And a tiny diesel generator with 60 ml tank

      • poVoq@slrpnk.net
        link
        fedilink
        English
        arrow-up
        5
        arrow-down
        2
        ·
        3 months ago

        Currently at step 9. Waiting for the roving bands of thugs to arrive 😅

    • umbrella@lemmy.ml
      link
      fedilink
      English
      arrow-up
      6
      ·
      edit-2
      3 months ago

      hey, AI defense turrets sound like a cool and totally not dangerous project. hope you have a decent GPU in your setup, good luck.

    • sugar_in_your_tea@sh.itjust.works
      link
      fedilink
      English
      arrow-up
      3
      ·
      3 months ago

      Yup. I don’t have a UPS (probably should; have a good surge protector though), and replacing CMOS batteries is way easier than dealing with the rest. Thanks for the reminder, I’ll go pick some up and swap it out every so often.

  • Khanzarate@lemmy.world
    link
    fedilink
    English
    arrow-up
    29
    ·
    3 months ago

    The only real solution is to make this an extended maintenance task. The batteries are cheap so an alert every 4 years is likely sufficient to replace the battery before it dies. You could do it every 2 or 3 years instead at your discretion.

    • IsoKiero@sopuli.xyz
      link
      fedilink
      English
      arrow-up
      15
      ·
      3 months ago

      The only real solution is to make this an extended maintenance task.

      This is the correct answer. No matter how reliable your power feed is you still need to reboot the server at some point for whatever reason and if CMOS battery is dead by then you’ll have the very same issue and you’ll need monitor and keyboard again. And even if you don’t mind about the RTC on board you’ll still lose the settings.

      I wonder why manufacturers haven’t switched over to supercapacitors or something else than a coin cell battery, but perhaps there’s a valid reason for it. I think that supercaps can’t hold charge as long as a coin cell, but if your board is completely cold for a year or so maybe losing bios settings isn’t that big of a deal.

      • Khanzarate@lemmy.world
        link
        fedilink
        English
        arrow-up
        4
        ·
        3 months ago

        Well they still have a finite life and are less replaceable than a battery. Even if it quadrupled the lifespan (which is a reasonably generous estimate given OP’s 4-year duration and wikipedia telling me supercapacitors last 10-15 years), it would still eventually need to be replaced and that would generally require resoldering it.

        I think a much better solution is 2 battery slots, one to be a backup battery, unused, and then when needed, an LED on the mobo can be turned on. Honestly OP could jury-rig up a similar system if he wanted to, although it’d be a bit ugly and anytime something is jury-rigged I don’t really think of it as reliable.

        • IsoKiero@sopuli.xyz
          link
          fedilink
          English
          arrow-up
          1
          ·
          3 months ago

          You could of course use some kind of socket or connetor for supercap, but as they last far less than I thought then I get why it doesn’t make sense. This thinkstation I’m writing with in my garage I got for free at old office is from 2011 and it’s still running original cmos battery. No idea if there’s any juice left on it, but at least it doesn’t complain anything at boot and once it refuses to boot it’ll become e-waste immediately (I do metal working, fix cars etc at the garage, so internals of this thing are far from clean, I think this is 3rd or 4th hardware for 10 years in here with only the SSD moved from setup to another).

  • hendrik@palaver.p3x.de
    link
    fedilink
    English
    arrow-up
    11
    ·
    3 months ago

    If you’re having frequent power outages, you might consider buying an UPS. Other than that, I’d just buy a new CMOS battery every few years. Mine seem to last way longer than 4 years. Maybe 8y or so.

  • superkret@feddit.org
    link
    fedilink
    English
    arrow-up
    9
    ·
    3 months ago

    From what I can see, I just need to replace the CMOS battery. But this computer has been running for over 4 years, so what is stopping this from happening again around 2028?

    Replace the CMOS battery again.

  • Possibly linux@lemmy.zip
    link
    fedilink
    English
    arrow-up
    7
    ·
    3 months ago

    Why you are at it you might want to check the battery in your smoke alarm. I think your are support to change the smoke alarm battery every 5 years.

    • crusty@lemmy.dbzer0.com
      link
      fedilink
      English
      arrow-up
      6
      ·
      edit-2
      3 months ago

      The battery in smoke detectors should be changed every year and you should ideally test the detectors using the little button monthly.

      In Norway we have an official smoke detector day which is on December 1. where we’re supposed to change the batteries. Its because Christmas is the high season for house fires.

      • sugar_in_your_tea@sh.itjust.works
        link
        fedilink
        English
        arrow-up
        4
        ·
        3 months ago

        That depends on the type of battery. I have some of the old school ones, which are “test every 6 months, replace every year,” but also a fancy schmancy lithium ion-powered one that should be good for 10 years (so test every 6 months, but replace after 10 years).

        • crusty@lemmy.dbzer0.com
          link
          fedilink
          English
          arrow-up
          4
          ·
          3 months ago

          Yea the lithium-ion batteries are pretty good, you can also get 10 year smoke detectors with a built in lithium battery. Also a psa, smoke detectors usually only last 10 years and need to be replaced after that. There’s often an expiry date on the detectors.

      • Possibly linux@lemmy.zip
        link
        fedilink
        English
        arrow-up
        1
        ·
        3 months ago

        It is 5 years in the US as it says it on the box. The battery can last 10 years but that is way to long from a safety perspective.

        • crusty@lemmy.dbzer0.com
          link
          fedilink
          English
          arrow-up
          1
          ·
          edit-2
          3 months ago

          Lithium batteries last 5-10 years, regular 9v alkaline batteries last about 12-18 months. Some sources recommend changing the batteries every 6th month but i personally think that’s a bit excessive.

          I only have a small 2 room apartment so i just got myself a cheap-ish optical smoke detector with a built in lithium battery. The battery should last 10 years which is how long smoke detectors last before they should be replaced.

      • Bronzie@sh.itjust.works
        link
        fedilink
        English
        arrow-up
        1
        ·
        3 months ago

        Just took over a house last year with smart detectors connected to a homebase, all Li-Ion. Can see the battery percentage in the app. No more December 1st checks for a long time!

  • Sparky@lemmy.blahaj.zone
    link
    fedilink
    English
    arrow-up
    6
    ·
    3 months ago

    If you’re the owner of the website, I suggest you look into those php errors

    
    Warning: simplexml_load_file(https://feeds.thefossrant.com/rss_feed.xml): failed to open stream: php_network_getaddresses: getaddrinfo failed: No address associated with hostname in /var/www/html/article.php on line 2
    
    Warning: simplexml_load_file(): I/O warning : failed to load external entity "https://feeds.thefossrant.com/rss_feed.xml" in /var/www/html/article.php on line 2
    
    Warning: Invalid argument supplied for foreach() in /var/www/html/article.php on line 5
    
    Warning: Invalid argument supplied for foreach() in /var/www/html/article.php on line 19
    
    Published on: 1970-01-01 00:00:00 UTC
    
    Tags:
    Image unavailable
    
    
  • TCB13@lemmy.world
    link
    fedilink
    English
    arrow-up
    5
    ·
    3 months ago

    Here’s the thing, you now know you’ve to replace the battery every 3 years or so, but I’ve SONY batteries running for 5 years and they’re fine. Now, your motherboard’s manufacturer is a piece of shit, the board should’ve just ignored the issue and proceeded to the OS. All modern operating systems sync the UEFI time whenever they get time from NTP so no need to halt the boot process.

  • EarMaster@lemmy.world
    link
    fedilink
    English
    arrow-up
    5
    ·
    3 months ago

    Some BIOS manufacturers allow you to disable all halts on errors. As soon as you connect to the network your system should be able to sync its internal clock.

    • MangoPenguin@lemmy.blahaj.zone
      link
      fedilink
      English
      arrow-up
      8
      arrow-down
      1
      ·
      3 months ago

      Some BIOS manufacturers allow you to disable all halts on errors.

      That will be reset to default if the CMOS battery is dead and power is removed though.

      • computergeek125@lemmy.world
        link
        fedilink
        English
        arrow-up
        3
        ·
        3 months ago

        Not on a flash based motherboard (so basically almost everything recent). On modern systems usually the only thing the battery powers is the clock, which is why they have a separate reset to defaults header/button/switch.

        (The CMOS memory of old is replaced with flash memory, al la SD Card or flash drive)

  • MangoPenguin@lemmy.blahaj.zone
    link
    fedilink
    English
    arrow-up
    3
    ·
    3 months ago

    Honestly just replace the CMOS battery on a schedule if it’s a big deal, a UPS is nice to have but it doesn’t really solve that specific problem.

  • knobpolisher@feddit.nl
    link
    fedilink
    English
    arrow-up
    2
    ·
    3 months ago

    I wonder… How about a hot swap cmos battery? Thinking you wire the cmos terminals to a few batteries in parallel Or 3 And add a voltage indicator for each of them

  • runesmite@lemmy.runesmite.com
    link
    fedilink
    English
    arrow-up
    2
    ·
    3 months ago

    I agree with you about an uninterruptible power supply. While a computer’s Power supply can normally handle about half a second of the wrong voltage, a UPS should provide you with minutes to hours of run time. While that won’t solve the CMOS going bad, it would probably reduce the amount of times a power outage would last long enough to shut down the computer - though that absolutely depends on the reliability of power in your area.

    Another option would be to look at different motherboard options. AsRock Rack (and I believe Supermicro) offer boards with BMCs, so you’d be able to change your BIOS settings from anywhere with a virtual KVM. They’re certainly pricier options, but a lovely convenience to have.

  • WasPentalive@lemmy.one
    link
    fedilink
    English
    arrow-up
    2
    ·
    3 months ago

    Can you replace the CMOS battery with a supercapacitor that is kept charged? This should not need to be replaced every 4 years, I think.

    • Bronzie@sh.itjust.works
      link
      fedilink
      English
      arrow-up
      2
      ·
      3 months ago

      We use these in our products at work and I’ve never heard about them failing before the equipment is replaced anyways. They are soldered.